The command can be run by entering one of the
following:
/usr/lpp/diagnostics/bin/uesensor -l | -a
/usr/lpp/diagnostics/bin/uesensor -t token -i index
[-v]
List
the sensors and their values in a text format. | |
-a |
List
the sensors and their values in a numerical format. For each sensor, the
following numerical values are displayed as: <token>
<index> <status> <measured value> <location
code> |
-t
token |
Specifies
the sensor token to query. |
-i
index |
Specifies
the sensor index to query. |
-v |
Indicates
to return the sensor measured value. The sensor status is returned by
default. |
- Display a list of the environmental sensors:
/usr/lpp/diagnostics/bin/uesensor -l
Sensor Token = Fan Speed
Status = Normal
Value = 2436 RPM
Location Code = F1
Sensor Token = Power Supply
Status =
Normal
Value = Present and operational Location Code = V1
Sensor
Token = Power Supply
*Status = Critical low
Value = Present and not
operational
Location Code = V2
- Display a list of the environmental sensors in a numerical list:
/usr/lpp/diagnostics/bin/uesensor -a
3 0 11 87 P1
9001 0 11 2345 F1
9004 0 11 2 V1
9004 1 9 2
V2
- Return the status of sensor 9004, index 1:
/usr/lpp/diagnostics/bin/uesensor -t 9004 -i 1 9
- Return the value of sensor 9004, index 1:
/usr/lpp/diagnostics/bin/uesensor -t 9004 -i 1 -v 2